A Near-Miss in the Grain Mill

Use FMEA logic to move from a near miss to preventive controls in brewery milling.

The near miss A grain hose crosses the mill-room walkway during setup. A brewer catches their boot, grabs the grist case, and avoids a fall. No injury does not mean no risk. It means the process gave you a warning while the cost was still low. FMEA in plain brewery language Failure mode -> effect -> control The walk asks what can fail, what happens if it fails, and what control makes the failure less likely or easier to catch. Weak reflex Tell people to be careful A control that prevents recurrence, not a lecture that fades. FMEA turns a…

Read the full lesson