Use a safe Time Travel recovery sequence: stop, locate, restore separately, validate, and replace deliberately.
A junior engineer drops DEV.CAMPAIGNS.TEST_EVENTS, then realizes the table held the only copy of a QA fixture needed for a release test. Recovery workflow: stop writing, identify the moment before loss, restore into a separate object, validate, then replace deliberately. The common shortcut is to apply a broad fix first, then search for evidence after the fact. That reverses the learning loop and makes cost, access, or quality debt harder to see. Stop Pause jobs that might recreate or overwrite the object. You preserve the evidence window before adding noise. Locate Find the drop time or statement ID in query…