Zum Hauptinhalt springen

Fix a Failed Try Step

Respond correctly when verification shows energy isolation has not worked.

lockout-tagout6 min read

The pallet wrapper moves during the try step after locks are applied. The team must treat the movement as failed isolation, not as a harmless twitch. Verification loop: stop exposure, diagnose the failed control, add the missing isolation or stored-energy control, then verify again. The dangerous shortcut is saying it only moved a little and starting work anyway. Small motion during verification proves the energy-control chain is incomplete. Before Main disconnect locked, air bled, try-start causes a brief turntable movement. The procedure lists no separate drive-enable disconnect. After Work remains stopped. The team finds and locks the drive-enable disconnect, updates…

Read the full lesson